Gas Fire Suppression Systems
Instant and safe fire suppression for server rooms and critical areas without water damage.
Service Definition
We provide design, installation, testing, and maintenance of clean agent gas fire suppression systems (FM200, Novec 1230) for server rooms, data centers, and museums.
The Problem
Water or chemical fire suppression destroys servers, electronics, and valuable archives, resulting in huge business interruption costs.
Our Solution
We provide clean agent gas systems that extinguish fire in under 10 seconds by absorbing heat, leaving no residue or moisture behind.
Scope of Service
How We Can Help You
We protect your critical digital infrastructure with a safe, tested, and reliable gas fire suppression system.
- 1Calculating safe gas concentrations to ensure occupant safety
- 2Supplying genuine, certified gas agents meeting global environmental standards
- 3Performing Room Integrity Fan Tests to ensure gas retention upon release
- 4Integrating gas control panels with the main building fire alarm panel
Our Work Process
Room measurement and structural integrity inspection
Field inspection to assess the site layout and fire hazard levels.
Volume calculations and gas concentration design
Analyzing requirements, hydraulic calculations, and electrical loads.
Pipe layout and discharge nozzle placement design
Drafting fire alarm, fighting, and evacuation safety plans.
Quotation & Approval
Providing complete technical and financial proposals for approval.
Cylinder, nozzle, and pipe installation
Supplying UL/FM certified devices and installation by experts.
Control panel, smoke sensors, and abort button installation
Performing hydraulic and functional tests for all scenarios.
Electrical/mechanical sequence testing and fan test
Handling submission and file tracking on the Salama digital portal.
Final handover, training, and certification
Official handover to owner/authorities, safety certification, and training.
Frequently Asked Questions
+Is the gas used safe for server rooms?
Yes, FM200 and Novec 1230 are clean agents that do not conduct electricity and leave no residue, making them perfectly safe for servers.
+Is the gas harmful to humans?
Both FM200 and Novec 1230 are safe for occupied spaces at design concentrations. Pre-discharge alarms allow occupants to exit safely.
+What is a Room Integrity Test?
It is a test that uses a door fan to measure how long the room can hold the gas concentration. Civil Defense requires it to be at least 10 minutes.
Request Consultation
Get in touch for a technical site visit and Civil Defense compliance evaluation.
Request a Site Visit+966 51 085 6006