Fire Fighting Systems

Gas Fire Suppression Systems

Instant and safe fire suppression for server rooms and critical areas without water damage.

Civil Defense Certified
NFPA Compliant
24/7 Support

Service Definition

We provide design, installation, testing, and maintenance of clean agent gas fire suppression systems (FM200, Novec 1230) for server rooms, data centers, and museums.

The Problem

Water or chemical fire suppression destroys servers, electronics, and valuable archives, resulting in huge business interruption costs.

Our Solution

We provide clean agent gas systems that extinguish fire in under 10 seconds by absorbing heat, leaving no residue or moisture behind.

Scope of Service

Enclosure volume study to calculate exact gas quantity requirements
Engineering design and discharge time calculations per NFPA 2001
Supply and installation of FM200 or Novec 1230 gas cylinders
Installation of copper/steel pipe network and gas discharge nozzles
Implementing pre-action double knock detection systems

How We Can Help You

We protect your critical digital infrastructure with a safe, tested, and reliable gas fire suppression system.

  • 1
    Calculating safe gas concentrations to ensure occupant safety
  • 2
    Supplying genuine, certified gas agents meeting global environmental standards
  • 3
    Performing Room Integrity Fan Tests to ensure gas retention upon release
  • 4
    Integrating gas control panels with the main building fire alarm panel

Our Work Process

01

Room measurement and structural integrity inspection

Field inspection to assess the site layout and fire hazard levels.

02

Volume calculations and gas concentration design

Analyzing requirements, hydraulic calculations, and electrical loads.

03

Pipe layout and discharge nozzle placement design

Drafting fire alarm, fighting, and evacuation safety plans.

04

Quotation & Approval

Providing complete technical and financial proposals for approval.

05

Cylinder, nozzle, and pipe installation

Supplying UL/FM certified devices and installation by experts.

06

Control panel, smoke sensors, and abort button installation

Performing hydraulic and functional tests for all scenarios.

07

Electrical/mechanical sequence testing and fan test

Handling submission and file tracking on the Salama digital portal.

08

Final handover, training, and certification

Official handover to owner/authorities, safety certification, and training.

Frequently Asked Questions

+
Is the gas used safe for server rooms?

Yes, FM200 and Novec 1230 are clean agents that do not conduct electricity and leave no residue, making them perfectly safe for servers.

+
Is the gas harmful to humans?

Both FM200 and Novec 1230 are safe for occupied spaces at design concentrations. Pre-discharge alarms allow occupants to exit safely.

+
What is a Room Integrity Test?

It is a test that uses a door fan to measure how long the room can hold the gas concentration. Civil Defense requires it to be at least 10 minutes.